Skip to Main Content
ADD A NEW IDEA

STAAD Concrete

Showing 64 of 64

Imperial System Desing input in RCDC

Imperial system of construction (Feet Inches) is still very much in use at remote locations in india. Beams, slabs etc allow input of mm in decimal range for equivalent "in" cross section, such functionality is unavailable in coumns and I have to ...
Guest over 2 years ago in  3 Needs review

RCDC FOOTING DETAIL STARTER BAR

I would like a new feature to be implemented in RCDC, when generating footing drawings , starter bar for the columns should be included in every footing detail as shown in the attached picture
Joseph Lucas Magare over 2 years ago in  2 Needs review

Waffle slab in RCDC / Staad Pro

Include the option to model, design and analyse waffle slab in RCDC/Staad Pro
Guest about 5 years ago in  1 Needs review

Add ACI 350-06

The environmental design of concrete needed for water retaining structures
Carlos Aguera about 3 years ago in  0 Planned

Testing ideas portal 2

This is a test without logging in
Guest over 3 years ago in  0 Needs review

Add support for Brazilian Codes

Please, add Brazilian codes: Some of the most important codes: ABNT-NBR 6118 (concrete design) ABNT-NBR 6122 (foundations design) ABNT-NBR 8800 (hot-rolled steel design) ABNT-NBR 14762 (cold-formed steel design) ABNT-NBR 7190 (wood design) ABNT-NB...
Guest over 1 year ago in  4 Needs review

RCDC DESIGN OF A BEAM OF ANY SHAPE CREATED IN USERTABLE

Hello i would like to suggest that RCDC to upgrade and enable it to design any type of beam shape which is created in USERTABLE of STAAD.Pro. i tried early to create a T beam in USERTABLE but after analysis this T beam was not recognized by RCDC
Joseph Lucas Magare almost 2 years ago in  1 Needs review

Third Design Code IS 456 + IS 13920-1993 + IS 13920-2016 in RCDC | STAAD

In RCDC we are using 2 types of Design Codes Combinations like this. IS 456 + IS 13920-1993 IS 456 + IS 13920-2016 Can't we have Third Design Code IS 456 + IS 13920-1993 + IS 13920-2016 in RCDC (SACD) or STAAD Pro like this? Because In IS 456 w...
Guest about 4 years ago in  1 Needs review

CONCRETE GRADE SELECTION IN RCDC

I think it will be better during design in RCDC,to select the concrete grade of column separately from that of wall.Concrete grade should be divided into two parts one for columns and the other one for walls.
Joseph Lucas Magare about 4 years ago in  0 Future consideration

Default material choosing (footing, column, beam, slab) one time in RCDC

Dear bentley software please make one time to choose default materials (concrete reinforcement) for design footing, column ,beam, slab in RCDC, because it waste too time when you select materials and you back to staad change something then you cho...
Guest about 2 years ago in  1 Needs review