Update of Canadian Code CSA 23.3 in STAAD Pro

For the design of concrete structures and foundations that will require permit approval in Canada, a recent code is expected. CSA code available in STAAD Pro Connect Edition is still CSA 23.3-94. Currently the latest code is 2019 but the 2014 is a...
Guest over 1 year ago in  3 Planned

COMBINED FOOTING, RAFT FOOTING IN RCDC

May you please include the design of raft foundation and combined footing in RCDC
Joseph Lucas Magare over 3 years ago in  0 Needs review

RCDC Foundation Overturning Safety Factor

similar to the sliding & uplift factors, would be helpful if there's an option to enter Overturning safety factor also.
Guest 8 months ago in  1 Needs review

BEAM DEFLECTION CHECK IN RCDC

This check should be implemented in RCDC as we know during design the reinforcement area maybe needed to be increased in order to pass the beam deflection check
Joseph Lucas Magare over 1 year ago in  1 Needs review

RCDC design all type footing

make RCDC design all type footing(single,combine,mat......)combine (RCDC,RCDC FE and staad advance foundation)
Guest over 2 years ago in  0 Needs review

RCDC - Option to carry out Combined Footing Design and Detailing in RCDC

There should be a feature in RCDC whereby you can group selected footing for combine footing design and detailing. Or, after RCDC is finish footing designs and the distance between adjacent footings are below a specified minimum, then RCDC should ...
Guest over 2 years ago in  0 Needs review

RCDC - Beam Design - Long term deflection check should be available

For the structures like Metro railway station and Industrial buildings, Clients are demanding to perform the long-term deflection check of the beam. RCDC should allow to perform the long-term deflection check for the beams selected by the user. Ge...
Abhijeet Gundaye over 1 year ago in  1 Needs review

RCDC enable read incline floor beam

No description provided
Guest over 2 years ago in  0 Needs review

SLANT BEAM DESIGN IN RCDC

May you please update the design of Slant beam in RCDC,as you may have a building has a certain slope from one grid to another
Joseph Lucas Magare over 3 years ago in  0 Future consideration

STAAD FOUNDATION BEARING PRESSURE DISPLAY FOR UPLIFT CASES

Currently in staad foundation max/min bearing pressure is shown only for the compression cases.Incase the minimum pressure is governed in uplift case the same is not shown in the summary table.Same can be updated in upcoming revisions.Also the bea...
Guest 9 months ago in  2 Needs review