Request to Include Ground Level and Water Table Depth in the Calculation Report – STAAD Foundation Advanced v2024

Include in the calculation output report the data corresponding to ground level and water table depth in STAAD Foundation Advanced V2024. Currently, the report displays parameters such as: Friction coefficient Passive pressure coefficient Subgrade...
Guest 3 months ago in  0 Needs review

Reintroduce Moment Diagram and Detailed Formulas in Flexural Check Report in STAAD Foundation Advanced V2024

We request the reintroduction of the moment diagram and the detailed formulas used during the flexural check in the report generated by STAAD Foundation Advanced V2024 (SFA V2024), as shown in previous versions of the software (SFA Version V9). Th...
Guest 3 months ago in  1 Needs review

Foundation Drawing Format in Output Reports – STAAD Foundation Advanced V2024

Proposal: It is suggested to restore the graphical format used in version V9 for representing foundations in both plan and elevation views within the output reports generated by STAAD Foundation Advanced. The drawings in version V9 were well-dimen...
Guest 3 months ago in  0 Needs review

Request to Include the Interaction Diagram in the Calculation Report – STAAD Foundation Advanced v2024

Please include the interaction diagram in the calculation output report for pedestals in STAAD Foundation Advanced 2024, as was done in version V9. Currently, the report shows the coordinates of the load points but does not include the associated ...
Guest 3 months ago in  0 Needs review

RCDC - Update Water Tank workflow using ACI code

Currently, water tank design is only available for the Euro Code. Please update for use with current ACI code.
Guest 10 months ago in  1 Needs review

Show Pile Unities in Results

Show pile unities in compression, shear and tension without having to click on a particular item in result Graphics in STAAD Foundation Advanced 2024.
Guest about 1 month ago in  0 Needs review

Beam - edit reinf for grouped beam - issue

This issue exists in all design codes.beams without grouping, edit reinforcement works properly. if beams are grouped, software unable to change the reinforcement.for grouped beams, quick detail and copy paste reinforcement works fine. Service cas...
Guest about 1 month ago in  0 Needs review

Combined wall design taking more time for specific case

refer Service case Service Case 1494311: [CS0270621] Combined wall design taking more timeAs alternate solution is available, it is marked as Low severity.
Guest about 1 month ago in  0 Needs review

Beam - edit reinf for grouped beam - issue

This issue exists in all design codes.beams without grouping, edit reinforcement works properly. if beams are grouped, software unable to change the reinforcement.for grouped beams, quick detail and copy paste reinforcement works fine. Service cas...
Guest about 1 month ago in  0 Needs review

Beam - Biaxial - Reinforcement Modified through quick detail no reflected in report

following issues are identified, program goes on non-responding mode using Quick detail tool. reinforcement changed using copy paste reinforcement tool is not reflected in the design calculation report. client file is of older version (11.03.01.10...