RCDC - Beam Design - Long term deflection check should be available

For the structures like Metro railway station and Industrial buildings, Clients are demanding to perform the long-term deflection check of the beam. RCDC should allow to perform the long-term deflection check for the beams selected by the user. Ge...
Abhijeet Gundaye over 2 years ago in  1 Needs review

adding clone job in the 'job setup' in STAAD Foundation

we conventionally add a new job and assign all the parameters from scratch while trying to replicate a similar footing desing within the same STAAD.Foundation file. however adding a cop/replicate/clone job might save time avoid the chance of missi...
Guest over 1 year ago in  0 Needs review

RCDC design all type footing

make RCDC design all type footing(single,combine,mat......)combine (RCDC,RCDC FE and staad advance foundation)
Guest over 3 years ago in  1 Needs review

SFA Foundation use uniform (average) Effective Bearing Pressure per AASHTO 10.6.1.4

Currently, SFA uses the highest corner pressure to design the foundation size bearing on soil. Please revise the SFA program to have an option for a soil supported foundation (versus a rock supported foundation) and provide revised foundation sizi...
Guest almost 2 years ago in  2 Needs review

COMBINED FOOTING, RAFT FOOTING IN RCDC

May you please include the design of raft foundation and combined footing in RCDC
Joseph Lucas Magare over 4 years ago in  1 Needs review

Need Option in RCDC to Design Beam supported by RC Column at one end and Steel bracket at other end

Need an Option to Design Beam supported by RC Column at one end and Steel bracket at other end. Currently RCDC doesn't recognize steel cupport and designing a beam s Cantilever which is not actual condition. This kind of Beam arrangment is require...
Guest 4 months ago in  0 Needs review

RCDC -Foundation design - Multiple Soil layers and Dispersed soil weight to be considered in the Stability checks -Buoyancy and overturning

For the foundation design, Buoyancy and overturning stability checks are performed. Presently Soil above the footing area is considered for the stability checks. The software should allow the user wants to consider the dispersed soil weight for th...
Abhijeet Gundaye over 2 years ago in  0 Needs review

Water Tank design as per IS codes in RCDC

No description provided
Guest almost 2 years ago in  1 Needs review

COMBINED FOOTING AND MAT/RAFT FOUNDATION FROM SFA TO RCDC FOR DETAILING

I would suggest SFA to add an option exporting designed combined footing and raft foundation to RCDC for detailing as we know RCDC is powerfully in producing structural drawings
Joseph Lucas Magare about 2 years ago in  1 Needs review

RCDC enable read incline floor beam

No description provided
Guest over 3 years ago in  0 Needs review