Skip to Main Content
ADD A NEW IDEA

All ideas

Showing 50 of 50

Update of Canadian Code CSA 23.3 in STAAD Pro

For the design of concrete structures and foundations that will require permit approval in Canada, a recent code is expected. CSA code available in STAAD Pro Connect Edition is still CSA 23.3-94. Currently the latest code is 2019 but the 2014 is a...
Guest over 1 year ago in  3 Planned

Possibility of Importing latest etabs file in RCDC

Currently we cannot import Etabs latest version files in RCDC. Creating a .accdb file takes a lot of time. So this capability is essential
Guest about 2 months ago in  0 Needs review

RCDC Foundation Overturning Safety Factor

similar to the sliding & uplift factors, would be helpful if there's an option to enter Overturning safety factor also.
Guest 8 months ago in  1 Needs review

Strap foundation design as per Indian code

Staad foundation advance supports design of structural strap of strap foundation as per ACI code , i.e not designed the structural strap of strap foundation as per Indian code. Hence add the features of design strap foundation along with structura...
Sahil Shaikh about 1 month ago in  0 Needs review

adding clone job in the 'job setup' in STAAD Foundation

we conventionally add a new job and assign all the parameters from scratch while trying to replicate a similar footing desing within the same STAAD.Foundation file. however adding a cop/replicate/clone job might save time avoid the chance of missi...
Guest 4 months ago in  0 Needs review

Modeling of trapezoidal pattern raft foundation in staad foundation advance

Staad foundation advance (SFA) has an option to assign plates of various thickness, but it should also have an option to model such plates in TRAPEZOIDAL PATTERN as shown in below images,which is frequently used to model raft foundation, also plac...
Sahil Shaikh 3 months ago in  0 Needs review

Design of Column with basement shear wall in RCDC

When the basement shear wall is modelled along with intermediate columns as shown in image, and such columns supposed to designed in RCDC , then RCDC devides the length of columns into small length/small segments as per meshing of adjacent shear w...
Sahil Shaikh 3 months ago in  3 Needs review

BEAM DEFLECTION CHECK IN RCDC

This check should be implemented in RCDC as we know during design the reinforcement area maybe needed to be increased in order to pass the beam deflection check
Joseph Lucas Magare over 1 year ago in  1 Needs review

RCDC Use Material Properties From Analysis

Have the material properties from the Staad analysis import from staad.
Guest 3 months ago in  1 Needs review

STAAD FOUNDATION BEARING PRESSURE DISPLAY FOR UPLIFT CASES

Currently in staad foundation max/min bearing pressure is shown only for the compression cases.Incase the minimum pressure is governed in uplift case the same is not shown in the summary table.Same can be updated in upcoming revisions.Also the bea...
Guest 9 months ago in  2 Needs review